Radyne MM200 Technical Information Seite 180

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 192
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 179
Appendix B MM200 High-Speed Microwave Modem
B-32 TM086Rev. 4.1
radMM200CommonLatchedAlarm1Status OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the value '00000000'B
Bit 0 = Glue logic FPGA status
Bit 1 = Test FPGA status
Bit 2-7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200CommonStatus 3 }
radMM200CommonLatchedAlarm2Status OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the value '00000000'B
Bit 0..7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200CommonStatus 4 }
-- --------------------------------------------------------------------------------------------------------------------
-- --------------------------------------------------------------------------------------------------------------------
-- MM200 Trap definitions.
-- Include Prefix for compatibility with SNMPv1 traps and procedures
-- employed by multi-lingual and proxy forwarding systems
radMM200MIBTrapPrefix OBJECT IDENTIFIER ::= { radMM200MIBTraps 0 }
radMM200ColdStartTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Unexpected restart."
::= { radMM200MIBTrapPrefix 1 }
radMM200AuthenticationFailureTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Received a message that has failed authentication."
::= { radMM200MIBTrapPrefix 2 }
radMM200ModMajorAlarmTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Modulator major alarm trap."
::= { radMM200MIBTrapPrefix 3 }
radMM200ModMinorAlarmTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Modulator minor alarm trap."
::= { radMM200MIBTrapPrefix 4 }
radMM200DemodMajorAlarmTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Demodulator major alarm trap."
::= { radMM200MIBTrapPrefix 5 }
radMM200DemodMinorAlarmTrap NOTIFICATION-TYPE
Seitenansicht 179